Cerabar PMC11, PMC21, PMP11, PMP21
26 Endress+Hauser
Environment
Ambient temperature range
Device Ambient temperature range
1)
PMC11
PMP11
–40 to +70 °C (–40 to +158 °F)
PMC21
PMP21
–40 to +85 °C (–40 to +185 °F)
PMC21
PMP21
Devices for hazardous areas: –40 to +70 °C (–40 to +158 °F)
1) Exception: the following cable is designed for an ambient temperature range of
–25 to +70 °C (–13 to +158 °F): Product Configurator order code for "Enclosed accessories" option "RZ".
Storage temperature range
–40 to +85 °C (–40 to +185 °F)
Climate class
Device Climate class Note
PMC11
PMP11
PMC21
PMP21
Class 3K5 Air temperature: –5 to +45 °C (+23 to +113 °F),
relative humidity: 4 to 95 %
satisfied according to IEC 721-3-3 (condensation not possible)
Degree of protection
Device Connection Degree of protection Option
1)
PMP21
PMP21
Cable5 m (16 ft) IP66/68
2)
NEMA type 4X/6P enclosure A
PMP21
PMP21
Cable10 m (33 ft) IP66/68
2)
NEMA type 4X/6P enclosure B
PMP21
PMP21
Cable25 m (82 ft) IP66/68
2)
NEMA type 4X/6P enclosure C
PMC11
PMP11
M12 plug IP65 NEMA type 4X enclosure L
PMC21
PMP21
M12 plug IP65/67 NEMA type 4X enclosure M
PMC11
PMP11
PMC21
PMP21
Valve plug ISO4400 M16 IP65 NEMA type 4X enclosure U
PMC11
PMP11
PMC21
PMP21
Valve plug ISO4400 NPT ½ IP65 NEMA type 4X enclosure V
1) Product Configurator order code for "Electrical connection"
2) IP 68 (1.83m H2O for 24 h)
Vibration resistance
Test standard Vibration resistance
IEC 60068-2-64:2008 Guaranteed for 5 to 2000Hz: 0.05g
2
/Hz
Electromagnetic
compatibility
Interference emission as per EN 61326-1 equipment B
Interference immunity as per EN 61326-1 (industrial environment)
NAMUR recommendation EMC (NE21)
Maximum deviation: 1.5% with TD 1:1
For more details please refer to the Declaration of Conformity.