Ceraphant PTP31B, PTP33B Diagnostics and troubleshooting
Endress+Hauser 41
9.2.2 List of diagnostic events
Diagnostic event Cause Corrective measure
Code Description
0 No error - -
C431
1)
Invalid position adjustment The calibration performed would cause the
sensor nominal range to be exceeded or
undershot.
Position adjustment + parameter of the current output
must be within the sensor nominal range
Check the position adjustment (see the ZRO
parameter)
Check the measuring range (see the STU and STL
parameters)
C432
alternating with
Ou1
1)
Invalid position adjustment,
output 1
The calibration performed causes the
switch points to be outside the sensor
nominal range.
Position adjustment + parameter of the hysteresis and
window function must be within the sensor nominal
range
Check the position adjustment (see the ZRO
parameter)
Check the switch point, switchback point for
hysteresis and window function
C432
alternating with
Ou2
1)
Invalid position adjustment,
output 2
The calibration performed causes the
switch points to be outside the sensor
nominal range.
Position adjustment + parameter of the hysteresis and
window function must be within the sensor nominal
range
Check the position adjustment (see the ZRO
parameter)
Check the switch point, switchback point for
hysteresis and window function
C469
alternating with
OU1 or OU2
Switch points output 1 or 2
violated
Switch point ≤ switchback point Check switch points at output
C485 Simulation active During simulation of the switch output or
current output, the device issues a warning
message for the duration of the simulation.
Switch off simulation
F270
2) 3)
Overpressure/low pressure Overpressure or low pressure present Check the process pressure
Check sensor range
Restart the device
Defect in electronics/sensor Defect in electronics/sensor Replace device
F437 Incompatible configuration Invalid device configuration Restart the device
Reset device
Replace device
F804 Overload at switch output 1
or 2 or both switch outputs
Load current > 250 mA per per output
4)
Increase load resistance at switch output
Switch output defective Check output circuit
Replace device
S140 Sensor signal outside of
permitted ranges
Overpressure or low pressure present Operate device in the specified measuring range
Sensor defective Replace device
S510 Turn down violated A change in the span results in a violation
of the turn down (max. TD 5:1)
Values for calibration (lower range value
and upper range value) are too close
together
Operate device in the specified measuring range
Check the measuring range
S803 Current loop 2 Impedance of load resistance at analog
output is too high
Check the cabling and load at the current output.
If the current output is not required, switch the
current output off via the configuration.