Description of device parameters Deltabar FMD71, FMD72
54
Factory setting "Pressure" measuring mode: "Sensor temperature HP"
"Level" measuring mode, Lin. mode "Linear": "Measured pressure LP"
"Level" measuring mode, Lin. mode "Activate table": "Measured pressure LP"
Display Depending on the selected measuring mode, the following measured values can be
displayed:
Measured value Measuring mode
Measured differential pressure Level, pressure
Corrected pressure Level, pressure
Measured pressure HP Level, pressure
Sensor press. HP Level, pressure
Sensor temperature HP Level, pressure
Measured pressure LP Level, pressure
Sensor press. LP Level, pressure
Sensor temperature LP Level, pressure
Level before linearization Level
Tank content Level
Process density Level
Temperature of electronics Level, pressure
4th Value (154)
Navigation Expert → Communication → HART output → 4th Value (154)
Write permission No write permissions. Parameter is read only.
Description The fourth value is displayed.
HART Input Value (155)
Navigation Expert → Communication → HART Input → HART Input Value (155)
Write permission No write permissions. Parameter is read only.
Description Display of the HART input value
HART Input Unit (156)
Navigation Expert → Communication → HART Input → HART Input Unit (156)