Deltabar FMD71, FMD72 Technical data
Endress+Hauser 117
15.2.10 Protocol-specific data
Manufacturer ID 17 (0x11)
Device type ID 39 (0x27)
HART specification 6.0
Device description files (DTM, DD) Information and files can be found:
www.endress.com
www.fieldcommgroup.org
HART device variables Measured values for PV (primary variable)
Differential pressure
Level linear (before lin.)
Level after linearization table
Measured values for SV, TV, QV (second, third and fourth variable)
Measured differential pressure
Corrected pressure
Measured pressure HP
Sensor pressure HP
Sensor temperature HP
Measured pressure LP
Sensor pressure LP
Sensor temperature LP
Level before linearization
Tank content
Electronic temperature
Supported functions Burst mode
Additional transmitter status