Technical data Deltabar FMD71, FMD72
124 Endress+Hauser
15.4.4 Vibration effects
Test standard Vibration effects
IEC 61298-3 ≤ Reference accuracy up to 10 to 60 Hz: ±0.35 mm (±0.01 in); 60 to 500 Hz: 2 g
15.4.5 Application limits
A high ratio between the level and head pressure or between the differential pressure and
static pressure can result in large measured errors. A maximum ratio of 1:10 is
recommended. For calculation purposes, please use the free "Applicator" calculation tool,
which is available online at "www.endress.com/applicator" or on CD-ROM.