EasyManua.ls Logo

Endress+Hauser FMR 231 - 6.7 Measuring point information; Communication level

Endress+Hauser FMR 231
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.7 Measuring point information
The following information about the measuring point can be read:
Communication level The matrix row "VA communication" can only be accessed via the the HART handheld
DXR 275 or Commuwin II.
Matrix field Display (or entry)
Measured value
V0H0
Principle measured value
V0H8
Distance to product surface
Bargraph shows echo quality: 1 segment = 5 dB
V0H9
Level before linearisation
Bargraph shows echo quality: 1 segment = 5 dB
Sensor data
V0H3
Application parameter
V0H5
Value for 4 mA
V0H6
Value for 20 mA
V2H0
Linearisation mode
V3H0
False echo suppression: 0 = factory set, 1 = customer set
V3H1
Dtance up to which echoes have been suppressed.
V3H2
Echo quality in dB: the higher, the better
V3H3
Microwave factor
V8H1
Currrent output min. 4 mA: 0 = off, 1 = on
V8H2
Unit of calibration: 0 = metre, 1 = feet
V8H3
Delay time on lost echo
V8H5
In safety distance: 0 = warning, 1 = alarm, 2 = alarm, self-holding
Information on measuring point
V9H3
xxyy: communications (xx) and software number (yy)
(xx = 80 = HART, yy = 10 = software version 1.0)
V9H4
HART communication address
Diagnosis
V9H0
Current diagnosis code
V9H1
Last diagnosis code
Matrix field Display (or entry)
VAH0
Measuring point Tag. No.
8 characters (ASCII) can be entered here
VAH3
Units of measured value (for handheld)
Chapter 6 Calibration with Display/Remote Operation Micropilot FMR 231
34 Endress+Hauser