Mounting device (for level
and point level
measurement)
Mounting the retaining bracket
Reference dimension A is used to define the mounting location of the retaining bracket depending
on the measuring range.
A
B
A0040283
 16 A defines the distance between the device flange and the start of the measuring range. Distance A
depends on the material of the scintillator (PVT or Nal).
A: PVT, distance : 172 mm (6.77 in)
A: Nal, distance : 180 mm (7.09 in)
B: Position and length of the measuring range
Mounting instructions
Keep the distance between the mounting clamps as large as possible
A0039103
 17 Installation overview, with mounting clamps and retaining bracket