EasyManua.ls Logo

Endress+Hauser HART Micropilot S FMR533 - Post-Installation Check

Endress+Hauser HART Micropilot S FMR533
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot S FMR533 4 to 20 mA HART Mounting
Endress+Hauser 21
L00-FMR532xx-00-00-06-en-003
3.5 Post-installation check
After the measuring device has been installed, perform the following checks:
Is the measuring device damaged (visual check)?
Does the measuring device correspond to the measuring point specifications such as process
temperature/pressure, ambient temperature, measuring range, etc.?
Is the flange marking correctly aligned ( ä 9)?
Have the flange screws been tightened up with the respective tightening torque?
Are the measuring point number and labeling correct (visual check)?
Is the measuring device adequately protected against rain and direct sunlight ( ä 68)?
9
Ø 78
17
16
detail A
flange hub for the connection
to flanges provided by the customer
flange hub
O-Ring 85.3 x 3.53,
included
(same material as
sensor seal)
mounting:
4 bolts M6 / 90°
e.g. DIN 912
E+H UNI flange
(max. 1 bar)
detail A:
flange adapter
(see under)
mount E+H UNI flange
pull off housing
Ø 62.5
Ø 99.5

Table of Contents