Technical data ISEmax compressed air cleaning unit (230 V AC)
18 Endress+Hauser
9.3 Disposal
The device contains electronic components. and must therefore be disposed of in accordance
with regulations on the disposal of electronic waste.
Observe the local regulations.
10 Technical data
10.1 Electrical connection
10.1.1 Supply voltage
230 V AC, 50 Hz
NOTICE
The device does not have a power switch!
A fuse with a maximum rating of 10 A must be provided by the customer.
Please observe the local installation guidelines.
10.1.2 Power consumption
300 VA; cos(phi) = 0.8
10.1.3 Cable specification
Permitted cable diameter:
6 to 12 mm (0.24 to 0.47") if using Pg 13.5
13 to 18 mm (0.51 to 0.71") if using Pg 21 (provided for mains supply line)
10.1.4 Electrical fuse of pump
Slow-blow 2.0 A
10.2 Performance characteristics
10.2.1 Conveying capacity
50 l/min (13.2 gal/min), at atmospheric pressure
10.2.2 Operating interval
Max. 3 minutes cleaning, break for at least six times the cleaning time
10.3 Environment
10.3.1 Ambient temperature
-10 to +55 °C (+10 to +130 °F)