EasyManua.ls Logo

Endress+Hauser iTEMP TMT162 - Certificates and Approvals; Storage and Transport; Mounting; Mounting Requirements

Endress+Hauser iTEMP TMT162
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting iTEMP TMT162
8 Endress+Hauser
3.3 Certificates and approvals
For certificates and approvals valid for the device: see the data on the nameplate
Approval-related data and documents: www.endress.com/deviceviewer → (enter the
serial number)
3.3.1 HART® protocol certification
The temperature transmitter is registered by the HART® FieldComm Group. The device
meets the requirements of the HART Communication Protocol Specifications, Revision 7
(HCF 7.6).
An overview of other approvals and certifications is provided in the Operating Instructions.
3.4 Storage and transport
Storage temperature Without display –40 to +100 °C (–40 to +212 °F)
With display –40 to +80 °C (–40 to +176 °F)
Maximum relative humidity: < 95 % as per IEC 60068-2-30
Pack the device for storage and transportation in such a way that it is reliably protected
against impact and external influences. The original packaging provides the best
protection.
Avoid the following environmental influences during storage:
Direct sunlight
Proximity to hot objects
Mechanical vibration
Aggressive media
4 Mounting
If stable sensors are used, the device can be fitted directly to the sensor. For remote mounting
to a wall or stand pipe, two mounting brackets are available. The illuminated display can be
mounted in four different positions.
4.1 Mounting requirements
4.1.1 Installation point
For use in hazardous areas, the limit values specified on the certificates and approvals must be
observed (see Safety Instructions).

Other manuals for Endress+Hauser iTEMP TMT162

Related product manuals