Electrical connection iTEMP TMT71, TMT72
20 Endress+Hauser
NOTICE
ESD - electrostatic discharge. Protect the terminals from electrostatic discharge. Failure
to observe this may result in the destruction or malfunction of parts of the electronics.
5.3 Connecting the sensor cables
5.3.1 Connecting to push-in terminals
2.
3.
4.
5.
1.
2.
3.
A
B
C
A0039468
 10 Push-in terminal connection, using the example of a head transmitter
Fig. A, solid wire:
1. Strip wire end. Min. stripping length 10 mm (0.39 in).
2. Insert the wire end into the terminal.
3. Pull the wire gently to ensure it is connected correctly. Repeat from step 1 if necessary.
Fig. B, fine-strand wire without ferrule:
1. Strip wire end. Min. stripping length 10 mm (0.39 in).
2. Press down on the lever opener.
3. Insert the wire end into the terminal.
4. Release lever opener.
5. Pull the wire gently to ensure it is connected correctly. Repeat from step 1 if necessary.