iTEMP TMT82 Electrical connection
Endress+Hauser 17
A0042426
On completion of the wiring, screw the screw terminals tightly. Tighten the cable glands
again. Refer to the information provided in the "Ensuring the degree of protection" section.
Screw the housing cover tightly again and fit the cover clamp back on. → 23
In order to avoid connection errors always follow the instructions in the post-connection check
section before commissioning!
5.2 Quick wiring guide
-
+
+
1
-
2
7
6
5
4
3
1
2
7
6
5
4
3
Sensor input 2
Sensor input 1
Bus connection
and supply voltage
Display connection
TC, mV
RTD, 4-, 3- and 2-wireΩ:
RTD, 3- and 2-wireΩ:
TC, mV
white
red
red
white
white
red
red
(black)
(yellow)
(black)
A0015015-EN
9 Terminal assignment of head transmitter