Output
Output signal Modbus
Physical interface RS485 in accordance with EIA/TIA-485 standard
Terminating resistor Not integrated
Signal on alarm
Depending on the interface, failure information is displayed as follows:
Local display
Status signal (in accordance with NAMUR Recommendation NE 107)
Plain text display
Operating tool via digital communication or service interface (CDI)
Status signal (in accordance with NAMUR Recommendation NE 107)
Plain text display
Linearization
The linearization function of the device allows the conversion of the measured value into any unit of
length or volume. Linearization tables for calculating the volume in cylindrical tanks are pre-
programmed. Other tables of up to 32 value pairs can be entered manually or semi-automatically.
Galvanic isolation
All circuits for the outputs are galvanically isolated from each other.