Levelflex FMP51 Modbus
Endress+Hauser 55
Center washer / centering star / centering weight
Ordering feature
610
"Accessory
mounted"
Meaning Thickness Diameter
OA Rod center washer 316L; pipe diameter DN80/3" + DN100/4" S = 4 mm (0.16 in) T = 75 mm (2.95 in)
OB Rod center washer 316L; pipe diameter DN50/2" + DN65/2-1/2" S = 4 mm (0.16 in) T = 45 mm (1.77 in)
OC Rope center washer 316L; pipe diameter DN80/3" + DN100/4" S = 4 mm (0.16 in) T = 75 mm (2.95 in)
OD Rod centering star PEEK; interface measurement; pipe diameter
DN50/2" + DN100/4"
S = 7 mm (0.28 in) T = 48 to 95 mm (1.9 to 3.7 in)
OE Rod centering star PFA; interface measurement; pipe diameter
DN40/1-1/2" + DN50/2"
P = 10 mm (0.39 in) Q = 37 mm (1.46 in)
OK Rope centering weight 316L for DN50/2" 60 mm (2.4 in) 45 mm (1.77 in)
OL Rope centering weight 316L for DN80/3" 30 mm (1.18 in) 75 mm (2.95 in)
OM Rope centering weight 316L for DN100/4" 30 mm (1.18 in) 95 mm (3.7 in)
Note on AlloyC flanges
AlloyC flanges always have an additional thread, even if they are not used with a coax probe.
Affected options of ordering feature 100 "Process connection": AEM, AFM, AGM, AQM, ARM, ASM,
ATM, CEM, CFM, CGM, CQM, CRM, CSM, CTM.
A0035223
20 Dimensions of AlloyC flanges; Dimensions: mm (in)