Levelflex FMP50/51/52/53/54/55/56/57 XA00634F-A
28 Endress+Hauser
Probe and electronics housing: Zone 0 / 探针和电子部件外壳 : 区域 0
FMP5x
Position / 位置 5 (Housing / 外壳 ) = A
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A; C:
1 canal used /
使用了 1 个槽
T6 ( 85 °C) -20 °C 40 °C 40 °C 40 °C 60 °C 40 °C 60 °C -20 °C -20 °C -20 °C - -
C:
2 canal used /
使用了 2 个槽
T6 ( 85 °C) -20 °C 32 °C 32 °C 32 °C 60 °C 32 °C 60 °C -20 °C -20 °C -20 °C - -
Position / 位置 5 (Housing / 外壳 ) = B, C
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A; C:
1 canal used /
使用了 1 个槽
T6 ( 85 °C) -20 °C 40 °C 40 °C 40 °C 60 °C 40 °C 60 °C -20 °C -20 °C -20 °C - -
C:
2 canal used /
使用了 2 个槽
T6 ( 85 °C) -20 °C 34 °C 34 °C 34 °C 60 °C 34 °C 60 °C -20 °C -20 °C -20 °C - -