Levelflex FMP55 HART Electrical connection
Endress+Hauser 35
Required tools/accessories:
For devices with a cover lock: Allen key AF3
Wire stripper
When using stranded cables: One ferrule for every wire to be connected.
2.
3.
1.
3 mm
10 (0.4)
10 (0.4)
4.
5.
5.
A0012619
 11 Dimensions: mm (in)
1. Loosen the screw of the securing clamp on the connection compartment cover and turn
the securing clamp 90° counterclockwise.
2. Unscrew the connection compartment cover.
3. Push the cable through the cable entry . To ensure tight sealing, do not remove the
sealing ring from the cable entry.
4. Remove the cable sheath.
5. Strip the cable ends over a length of 10 mm (0.4 in). In the case of stranded cables, also
fit ferrules.
6. Firmly tighten the cable glands.