Mounting Levelflex FMP55 HART
32 Endress+Hauser
A
B
C
C
r = 100 (4)
min
r = 100 (4)
min
A0014794
7 Connecting the cable. There are the following possibilities:
A Angled plug at the probe
B Angled plug at the electronics housing
C Length of the remote cable as ordered
6.2.4 Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned:
A0013713
1. Unscrew the securing screw using an open-ended wrench.
2. Rotate the housing in the desired direction.
3. Tighten the securing screw (1,5 Nm for plastics housing; 2,5 Nm for aluminium or
stainless steel housing).