EasyManua.ls Logo

Endress+Hauser Levelflex FMP55 HART - Turning the Transmitter Housing

Endress+Hauser Levelflex FMP55 HART
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting Levelflex FMP55 HART
32 Endress+Hauser
A
B
C
C
r = 100 (4)
min
r = 100 (4)
min
6 Nm
(4.42 lbf ft)
6 Nm
(4.42 lbf ft)
6 Nm
(4.42 lbf ft)
6 Nm
(4.42 lbf ft)
A0014794
 7 Connecting the cable. There are the following possibilities:
A Angled plug at the probe
B Angled plug at the electronics housing
C Length of the remote cable as ordered
6.2.4 Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned:
max.350°
8mm
8mm
A0013713
1. Unscrew the securing screw using an open-ended wrench.
2. Rotate the housing in the desired direction.
3. Tighten the securing screw (1,5 Nm for plastics housing; 2,5 Nm for aluminium or
stainless steel housing).

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP55 HART

Related product manuals