Liquicap M EG 05 022 / XA00346F-C
18 Endress+Hauser
Zone 22 Application: For the connetion to non-intrinsically safe circuits.
Electronic
insert
Type of protection/
level of protection
Electrical
data
Ambient temperature
electronic
Maximum surface
temperature (Ta max.)
Housing
ingress
protection
FEI50H II 3 D
Ex tD A22 IP6X
T 100 °C
Ui ≤ 30 V
Ii ≤ 120 mA
Pi ≤ 1 W
Ci ≤ 2.4 nF
Li ≤ 0
–50 °C ≤ Ta ≤ +60 °C +100 °C IP65
FEI57C II 3 D
Ex tD A22 IP6X
T 100 °C
Ui ≤ 19.2 V
Ii ≤ 108 mA
Pi ≤ 1 W
Ci ≤ 2.4 nF
Li ≤ 0
–50 °C ≤ Ta ≤ +60 °C +100 °C IP65
FEI55 II 3 D
Ex tD A22 IP6X
T 100 °C
Ui ≤ 36 V
Ii ≤ 100 mA
Pi ≤ 1 W
Ci ≤ 2.4 nF
Li ≤ 0
–50 °C ≤ Ta ≤ +60 °C +100 °C IP65
FEI57S II 3 D
Ex tD A22 IP6X
T 100 °C
Ui ≤ 16.1 V
Ii ≤ 100 mA
Pi ≤ 1 W
Ci ≤ 2.4 nF
Li ≤ 0
–50 °C ≤
Ta ≤ +60 °C +100 °C IP65
FEI58 II 3 D
Ex tD A22 IP6X
T 100 °C
Ui ≤ 18 V
Ii ≤ 52 mA
Pi ≤ 170 mW
Ci ≤ 0
Li ≤ 0
–50 °C ≤ Ta ≤ +60 °C +100 °C IP65
Electronic
insert
Type of protection/
level of protection
Power supply Relay circuit
FEI52
(3 wire PNP)
II 3 D
Ex tD A22 IP6X
T 100 °C
10... 55 V DC –
FEI54
(Relay)
II 3 D
Ex tD A22 IP6X
T 100 °C
19...253 V AC 253 V AC / 6 A *
1500 VA / cos ϕ = 1
750 VA / cos ϕ > 0.7
19... 55 V DC 30 V DC / 6 A *
125 V DC / 0.2 A
* for T13 housing: 4 A