Operation Liquiline CM44P
122 Endress+Hauser
The calculation of the remaining capacity depends on the following factors:
• Flow rate
• Volume of the exchanger
• Salinity of the water at the exchanger inlet
• Total volume capacity of the resin
• Degree of efficiency of the exchanger
Menu/Setup/Additional functions/Mathematical functions/MF1 to 8/Mode = Cation exchanger capacity
Function Options Info
Cond IEX output Read only
Cond IEX input
Flow rate
Remaining capacity
Remaining op. time
Time until %0B
1)
Configuration
Calculation Selection
• Off
• On
Factory setting
Off
On/off switch for the function
Unit of volume Selection
• l
• gal
Factory setting
l
Exchanger volume 0.0 to 99999
Factory setting
0.0
Volume of the cation exchanger
Unit depending on the option selected in Unit of
volume
TVC Resin 0.0 to 99999 eq/l or
eq/gal
Factory setting
0.0 eq/l
TVC = total volume capacity
Unit as equivalent per Unit of volume
Resin efficiency 1.0 to 100.0 %
Factory setting
100.0 %
For information on the resin efficiency, refer to
the data provided by the manufacturer of the
resin used.
Set remaining capacity Selection
• Yes
• No
Factory setting
No
Before you start monitoring, specify the
remaining capacity of the exchanger resin.
This value makes allowances for the re-use of
resin that has already been used.
If a value is not entered manually, 100 % is
taken as the initial value for calculating the
current remaining capacity.
Remaining capacity
Set remaining capacity = Yes
0.0 to 100.0 %
Factory setting
0.0 %
Warning limit 1.0 to 100.0 %
Factory setting
20.0 %
Specify the remaining capacity at which the
transmitter should display a diagnostic message.