Technical data Liquiphant FTL31
38 Endress+Hauser
0 +50 +100 +150
–40
+32 +122 +212 +302
–40
–20
+70
[°C]
–4
+158
[°F]
0
+32
[°C]
[°F]
+50
+122
T
a
T
P
1
2
T
a
T
p
+90
+194
A0020869
 18 Derating curve: 150 °C (302 °F)
1 I
max
: 200 mA (DC-PNP), 250 mA (AC/DC)
2 I
max
: 150 mA (DC-PNP), 150 mA (AC/DC)
Ta Ambient temperature
Tp Process temperature
12.3 Process
NOTICE
Note the pressure and temperature derating depending on the process connection selected.
Process temperature range –40 to +100 °C (–40 to +212 °F)
–40 to +150 °C (–40 to +302 °F)
Process pressure range Max. –1 to +40 bar (–14.5 to +580 psi)
Density
> 0.7 g/cm³ (optionally available: > 0.5 g/cm³)
State of aggregation Liquid
Viscosity 1 to 10 000 mPa⋅s dynamic viscosity
Solids contents ø < 5 mm (0.2 in)
Lateral loading capacity Lateral loading capacity of the tuning fork: max. 200 N