Mounting Liquiphant FTL51B
8 Endress+Hauser
Storage temperature
–40 to +80 °C (–40 to +176 °F)
Optional: –50 °C (–58 °F), –60 °C (–76 °F)
3.3.2 Transporting the device
Transport the device to the measuring point in the original packaging
Hold the device by the housing, temperature spacer, flange or extension pipe
Do not bend, shorten or extend the tuning fork
A0034846
 2 Handling the device during transportation
4 Mounting
L
WARNING
Loss of protection rating if the device is opened in a wet environment.
Only open the device in a dry environment!
Mounting instructions
Any orientation for device with short pipe up to approx. 500 mm (19.7 in)
Vertical orientation for device with long pipe
Minimum distance between the fork tip and the tank wall or pipe wall: 10 mm (0.39 in)