EasyManua.ls Logo

Endress+Hauser Liquiphant FTL62 - Access via Local Display and Bluetooth

Endress+Hauser Liquiphant FTL62
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection Liquiphant FTL62
28 Endress+Hauser
Terminal assignment
>0,5
COM
MIN
MAX
>0,7
+
1
2
L- L+
7
33
37
d4
z4
8
34
38
d2
z2
z6 d6
.
-
1 2
!
!
4
3
1
2
1
3
4
M12
L+ L- PE
B
A
A0036065
 22 PFM output, electronic insert FEL67
A Connection wiring with terminals
B Connection wiring with M12 plug in housing according to EN61131-2 standard
7/ 8: Nivotester FTL325P 1 CH, FTL325P 3 CH input 1
33/ 34: Nivotester FTL325P 3 CH input 2
37/ 38: Nivotester FTL325P 3 CH input 3
d4/ d2: Nivotester FTL375P input 1
z4/ z2: Nivotester FTL375P input 2
z6/ d6: Nivotester FTL375P input 3
Connection cable
Maximum cable resistance: 25 Ω per core
Maximum cable capacitance: < 100 nF
Maximum cable length: 1 000 m (3 281 ft)