Liquiphant M FTL50(H), FTL51(H)
Endress+Hauser 29
Tri-Clamp
1 ½" = ø50.5 mm
2" = ø64.0 mm
ISO 2852
TC2
TE2
L00-FTL5xxxx-06-05-xx-xx-009
Clamping ring and
front seal
installed on site
In conformity with
FDA*
max. 16 bar
max. 120 °C
max. 2 bar
max. 150 °C
Threaded pipe joint
DN 32
DN 40
DN 50
DIN 11851
with screw cap
MA2
MC2
ME2
L00-FTL5xxxx-06-05-xx-xx-010
Sealing ring with collar,
installed on site
In conformity with
FDA*
DN 32, DN 40:
max. 40 bar to 100 °C
max. 25 bar to 140 °C
DN 50:
max. 25 bar
max. 140 °C
Flush-mounted for 1"
welding neck
Factory standard
Endress+Hauser with
silicone seal
and screw cap:
supplied
EE2
L00-FTL5xxxx-06-05-xx-xx-011
Welding neck
(fork can be
positioned)
Endress+Hauser
52001047
In conformity with
FDA*
See "Accessories"
max. 40 bar
max. 100 °C
max. 25 bar
max. 150 °C
Aseptic
DN 50
DIN 11864-1
Form A
for pipe DIN 11850
with screw cap
HE2
L00-FTL5xxxx-06-05-xx-xx-012
Sealing ring,
installed on site
In conformity with
FDA*
max. 25 bar
max. 140 °C
DRD
With clamped flange
PE2
L00-FTL5xxxx-06-05-xx-xx-013
Welding flange with
PTFE flat seal
(fork can be
positioned)
Endress+Hauser
52002041
In conformity with
FDA*
See "Accessories"
(or installed on site)
max. 40 bar
max. 100 °C
max. 25 bar
max. 150 °C
SMS
2"
(DN 51)
with screw cap
UE2
L00-FTL5xxxx-06-05-xx-xx-014
Sealing ring,
installed on site
In conformity with
FDA*
max. 25 bar
max. 140 °C
Varivent
for piping
DN 65
O.D. 3"
I.P.S. 3"
WE2
L00-FTL5xxxx-06-05-xx-xx-015
Clamping ring and
O-ring seal,
installed on site
In conformity with
FDA*
See specification as per
Tuchenhagen VARIVENT-
Inline housing but:
max. 25 bar
max. 150 °C
* FDA approved materials according to 21 CFR Part 177.1550/2600
Process connection Dimensions Accessories Pressure
Temperature
66.5
66.5
55.5
66.5
66.5
66.5
56.5
ø68

Table of Contents