Liquistation CSF48 Programming
59
The settings that depend on the sampling mode are listed in the "Program type: Basic" section.
Enable subprogram Options
•Immediate
Individual dates
Repeating date
•Interval
Deactivation
Factory setting
Immediate
Immediate:
The subprogram is enabled immediately.
Individual dates:
Set the start and stop dates for enabling the subpro-
gram.
Repeating date:
Set the start condition, activity time and repetition
interval for the subprogram.
Interval:
Set the start condition, activity time and inactivity
time for the subprogram.
Deactivation:
Only visible if there is more than one subprogram
If Enable subprogram Individual dates is selected:
Individual dates
Set the start and stop times for the subprogram. Enter a new date via "INSERT". Delete a date via "DELETE". You can
assign a maximum of 25 start and stop dates.
If Enable subprogram Repeating date is selected:
Start condition Options
•No delay
Date/Time
•Time
Factory setting
No delay
No delay:
The subprogram is started when the program is enab-
led.
Date/Time:
Set the start date and start time for enabling the sub-
program.
Time:
Set the start time for enabling the subprogram.
Activity time 00:01 to 99:59 HH:MM
Factory setting
00:01 HH:MM
Specify how long the subprogram should be active in
hours and minutes.
The time to be selected depends on the setting for the
repetition mode.
Multiple date
Repetition mode Options
Daily interval
•Weekly interval
•Days of week
Factory setting
Daily interval
Daily interval:
Specify whether the subprogram should be repeated
every day.
Weekly interval:
Specify whether the subprogram should be repeated
every week.
Days of week:
Specify whether the subprogram should be repeated
on certain days of the week.
--> Select the days of the week in the subsequent
menu item.
Path: Menu/Setup/Sampling programs