Appendix Liquisys M CCM223/253
120 Endress+Hauser
C
A6A2
A1
A3
A4 A5
A
B
Z
O332
B5
O333
B2
O3(3)
B3
O331
B4
O3(2)
O321
O O1 O2 O3(1) O311 O312 O313
C15C12 C13 C14C11
F2F1F F5F3 F4 F6
Z5Z1 Z2 Z3 Z4
Z6
C15
C14 C15
Only display switchover!
CURRENT INPUT
SETUP 2
SETUP 1
CURRENT OUTPUT
1st error displayed
(if present)
Other errors are
displayed
(up to max. 10 errors)
Meas. value display
Current input in %
Meas. value display
Current input in mA
Controller switch-off
by sample stream
INSOff;
Select display unit
; ppm; ppbmg/l
Cont. switch-off
by current input
InputOff;
Select current range
020 mA4–20 mA;
Enter 0/4 mA value
0 ... 20 (5) mg/l
0 ... 50 °C
0.00;
0 °C;
Enter 20 mA value
0 ... 20 (5) mg/l
0 ... 50 °C
2.0 (0.5);
50 °C;
lin = linear
PH compensation
ManuOff;
Sw.-off direction
for current input
HighLow;
Select sensor
141; 240; 241;
963; 120
140;
Select current output
Output2Output1;
Enter
DPD value
Value of last cal.
Delay for controller
switch-off sam. stream
0 ... 2000 s0 s
Delay for cont.
switch-off curr. input
0 ... 2000 s0 s
Tab = Table
sim = Simulation
Manual
pH compensation
pH 4.00 ... 9.00
last comp. value
Delay for contr.
swi.-on sam. stream
0 ... 2000 s0 s
Delay for cont.
sw.-on current input
0 ... 2000 s0 s
Enter simulation
0 ... 22.0 mA
val.
current value
Select table
options
editread
Enter no. of
table pairs
1 ... 101
Select
table pairs
1 ... no. Table pair
asign
1
Enter correct
process temperature
0 ... 50 °C
current meas. value
Select
digital input 1
Clean trig.ext.Hold
Sw.-off limit value
for current input
0 ... 100%50%
Enter temperature
difference (offset)
5.0 ... + 5.0 °C
current offset
MEAS. VALUE
DISPLAY
with
TEMPERATURE
READING
in °C
Zero calibration
(only if A1 = 120 or 963)
yesno;
Calibration status
is displayed
Exxxo.k.
Store
calibration
no; newyes;
Slope is
displayed
min. 25% (3%)
max. 500%
100%
CALIBRAT
Cl
2
/ ClO
2
ALARM
Select contact type
=
Latch = latching c.
Momen momentary c.
Select unit of alarm
delay
smin;
Define
error current
2.4 mA22 mA;
Select error number
1 ... 2551
Enable alarm
contact
noyes;
Alarm delay
0 ... 2000 min (s)
(dep. on F2)
0 min (s)
Feedforward control
to PID cont.
lin = linearOff;
Meas. value display
Temperature reading in °F
Meas. value display
no temp. display
Meas. value display
Sensor current in nA
Edit:
Code 22
Read:
any code
Edit:
Code 22
Read:
any code
Select meas. unit for
2nd current output
; mg/l; ppm; ppb; Contr°C
Zero calibration
yes
(only if A1 = 120)
no;
Calibration status is
displayed
Exxxo.k.
Store calibration
result
no; newyes;
CALIBRATION
zero
(CCS120)
Operating matrix versions EK and ES
A0002633-EN