Appendix Liquisys M CCM223/253
122 Endress+Hauser
R263
P114
R283
R243
R233
R213
R273
R264
P115
R284
R244
R234
R214
R2(7)
R2(6)
P111
R2(8)
R2(4)
R2(3)
R2(1)
R271
R261
P112
R281
R241
R231
R211
R262
P113
R282
R242
R232
R212
P1(1)
R1
P
R
R272
E141
E131
E121
S2
E142
E132
E122
S1
E1(4)
E1(3)
E1(2)
S S4 S5S3
E143 E144
E133 E134
E123 E124
E113 E114
E111 E112E1(1)
I1
E
I
CHECK
RELAY
Select alarm threshold
monitoring
Low; High
LoHi; Lo!; Hi!; LoHi!
Off;
Select contact to
be configured
Rel2; Rel3; Rel4Rel1;
Select start pulse
i+ext = internal + external
ext = external i+stp = int. w. suppression by ext.
int = internal
Define rinse time
0 ... 999 s30 s
Define pause time
1 ... 7200 min
360 min
Define minimum
pause time
1 ... 3600 min
120 min
Set lower
alarm threshold
0 ... 19.9 (4.9) mg/l
0.00 mg/l
Enter setpoint
0 ... 20 (5) mg/l
0.5 (0.1) mg/l
Enter control
gain K
p
0.01 ... 100.001.00
Enter integral action time
T
n
(0.0 = no I comp.)
0.0 ... 999.9 min0.0 min
Enter integral action time
T
n
(0.0 = no I comp.)
0.0 ... 999.9 min0.0 min
Enter control
gain K
p
0.01 ... 100.001.00
Enter setpoint
0 ... 20 (5) mg/l
0.5 (0.1) mg/l
Enter switch-on
temperature
0 ... 50 °C50 °C
Enter switch-off
temperature
0 ... 50 °C50 °C
Set pick-up
delay
0 ... 2000 s0 s
Set pick-up
delay
0 ... 2000 s0 s
Select switch-on point
of contact
0 ... 20 (5) mg/l
20 (5) mg/l
Select switch-off point
of contact
0 ... 20 (5) mg/l
20 (5) mg/l
Set upper
alarm threshold
0.1 ... 20 (5) mg/l
20.00 (5.00) mg/l
Enter pre-rinse time
0 ... 999 s20 s
Chlorine / ClO2
Switch function R2(7)
on or off
OnOff;
Clean =
Chemoclean
(only with Rel3 and Rel4)
Switch function R2(6)
on or off
OnOff;
Timer
Switch function R2(8)
on or off
OnOff;
3-point step controller
Cl2 / ClO2
(only with Rel3 and Rel4)
Switch function R2(4)
on or off
On; Basic; PID+BOff;
PID controller
Cl2 / ClO2
Switch function R2(3)
on or off
On; Basic; PID+BOff;
LC °C =
Limit contactor
T
Switch contact R2(1)
on or off
OnOff;
LC PV =
limit contactor
Cl2 / ClO2
Alarm delay
0 ... 2000 min (s)
(dep. on F2)
0 min (s)
SERVICE
E+H SERVICE
INTERFACE
Module software
SW Version
Hardware version
HW Version
Serial number
is displayed
Module identification
is displayed
Module
is displayed
identification
Module
is displayed
identification
Module
is displayed
identification
Serial number
is displayed
Serial number
is displayed
Serial number
is displayed
Hardware version
HW Version
Hardware version
HW Version
Hardware version
HW Version
Module software
SW Version
Module software
SW Version
Instrument software
SW Version
Enter address
HART: ... 15 or
PROFIBUS: 1 ...
0
126
Rel (= relay)
Main (= mainboard)
Trans (= transmitter)
Contr (= controller)
Manual Hold
OnOff;
Enter Hold
0 ... 999 s
dwell time
10 s
Enter SW upgrade
release code (Plus pack.)
0 ... 99990
Select language
GER; FRA;
ITA; NEL; ESP
ENG;
Configure Hold
CAL = with Cal.
Setup = for param. no
S+C = for param. + cal.
= no Hold
Select process
monitoring
AC; CC; AC CC
AC!; CC!; ACCC!
Off;
I2
Tag description
@@@@@@@@
A0002635-EN