F5 F6
P124
P124
R263
P114
R283
R253
R243
R233
R223
R223
R213
P125
R273
P125
R264
P115
R284
R254
R244
R234
R224
R224
R214
F2
P121
R2(7)
P121
R2(6)
P111
R2(8)
R2(5)
R2(4)
R2(3)
R2(2)
R2(2)
R2(1)
F3
P122
R271
P122
R261
P112
R281
R251
R241
R231
R221
R221
R211
F4
P123
P123
R262
P113
R282
R252
R242
R232
R222
R222
R212
F1
P1(2)
P1(2)
P1(1)
R1
F
P
R
R272
ALARM
CHECK
RELAY
Select contact type
Momen = momentar c
Latch = latching c.
y .
Select alarm threshold
monitoring
Low!; High!; LoHi!
Low; High; Lo HiOff;
Select alarm threshold
monitoring
Low!; High!; LoHi!
Low; High; Lo HiOff;
Select alarm threshold
monitoring
Low; High
Lo Hi; Low! High!; LoHi!
Off;
;
Select contact to
be configured
Rel2; Rel3; Rel4Rel1;
Set lower
alarm threshold
0 ... 1490 mV0 mV
Select start pulse
i+ext = internal + external
ext = external i+stp = int. w. suppression of ext.
int = internal
Set lower
alarm threshold
pH 4 ... 8.9pH 4.00
Define rinse time
0 ... 999 s30 s
Define pause time
1 ... 7200 min
360 min
Define min. pause
time
1 ... 3600 min
120 min
Set upper
alarm threshold
pH 4.1 ... 9pH 9.00
Enter control
gain K
p
0.01 ... 100.001.00
Enter integral action time
T
n
(0.0 = no I comp.)
0.0 ... 999.9 min0.0 min
Enter integral action time
T
n
(0.0 = no I comp.)
0.0 ... 999.9 min0.0 min
Enter integral action time
T
n
(0.0 = no I comp.)
0.0 ... 999.9 min0.0 min
Enter control
gain K
p
0.01 ... 100.001.00
Enter control
gain K
p
0.01 ... 100.001.00
Enter setpoint
pH 4 ... 9pH 7.20
Set switch-on
temperature
0 ... 50 °C50 °C
Set switch-off
temperature
0 ... 50 °C50 °C
Set pick-up
delay
0 ... 2000 s0 s
Set pick-up
delay
0 ... 2000 s0 s
Set pick-up
delay
0 ... 2000 s0 s
Set pick-up
delay
0 ... 2000 s0 s
Select contact
switch-on point
pH 4 ... 9
pH 9
Select contact
switch-off point
pH 4 ... 9
pH 9
Select contact
switch-on point
0 ... 1500 mV
1500 mV
Select contact
switch-off point
0 ... 1500 mV
1500 mV
Set upper
alarm threshold
10 ... 1500 mV1500 mV
Select process
monitoring
AC; AC!Off;
Enter pre-rinse time
0 ... 999 s20 s
Select process
monitoring
AC; CC; AC CCOff;
AC!; CC!; ACCC!
Select process
monitoring
AC; CC; AC CC
AC!; CC!; ACCC!
Off;
ORP mV
(dep. on B1)
pH
(dep. on B1)
Chlorine / ClO2
Select unit for
alarm delay
smin;
Alarm delay
0 ... 2000 min (s)
(depending on F2)
0 min (s)
Switch function R2(7)
on or off
OnOff;
Clean =
Chemoclean
(only with Rel3 and Rel4)
Switch function R2(6)
on or off
OnOff;
Timer
Switch function R2(8)
on or off
OnOff;
3-point step controller
Cl2 / ClO2
(only with Rel3 and Rel4)
Switch function R2(5)
on or off
On; Basic; PID+BOff;
PID controller
pH
Switch function R2(4)
on or off
On; Basic; PID+BOff;
PID controller
Cl2 / ClO2
Switch function R2(3)
on or off
OnOff;
LC °C =
Limit contactor
T
Switch function R2(2)
on or off
OnOff;
LCORP =
Limit contactor
ORP
(dep. on B1)
LC pH =
Limit contactor
pH
(dep. on B1)
Switch function R2(2)
on or off
OnOff;
Switch function R2(1)
on or off
OnOff;
LC PV =
Limit contactor
Cl2 / ClO2
Alarm delay
0 ... 2000 min (s)
(depending on F2)
0 min (s)
Alarm delay
0 ... 2000 min (s)
(depending on F2)
0 min (s)
Define
error current
2.4 mA22 mA;
Select error number
1 ... 2551
Enable alarm
contact
noyes;
Alarm delay
0 ... 2000 min (s)
(depending on F2)
0 min (s)
Enter setpoint
0.5 (0.1) mg/l;
0.5 ppm
500 ppb;
0 ... 20 (5) mg/l
; 0 … 20 ppm
0 … 20000 ppb
Set lower
alarm threshold
0.00 mg/l;
0.00 ppm
0 ppb;
0 ... 20 mg/l
; 0 … 20 ppm
0 … 20000 ppb
Set upper
alarm threshold
20.00 mg/l;
20.00 ppm
20000 ppb;
0 ... 20 mg/l
; 0 … 20 ppm
0 … 20000 ppb
Enter setpoint
0.5 (0.1) mg/l;
0.5 ppm
500 ppb;
0 ... 20 (5) mg/l
; 0 … 20 ppm
0 … 20000 ppb
Select contact
switch-on point
20 (0.5) mg/l;
20 ppm
20000 ppb;
0 ... 20 (5) mg/l
; 0 … 20 ppm
0 … 20000 ppb
Select contact
switch-off point
20 (0.5) mg/l;
20 ppm
20000 ppb;
0 ... 20 (5) mg/l
; 0 … 20 ppm
0 … 20000 ppb