Installation Micropilot FMR50 HART
20 Endress+Hauser
100%
0%
B
A
C
H
øD
A0018872
Device A [mm (in)] B [m (ft)] C [mm (in)] H [m (ft)]
FMR50 150 (
5.91)
> 0.2 (0.7) 50 to 250 (1.97 to 9.84) > 0.3 (1.0)
6.3 Installation in vessel (free space)
6.3.1 Horn antenna encapsulated (FMR50)
Alignment
Align the antenna vertically to the product surface.
A marking at the threaded connection enables alignment of the antenna. This marking
must be aligned towards the tank wall as well as possible.