Micropilot FMR60
Endress+Hauser V. 4, Rev. 2, 19-03-2018 29
Inner nozzle diameterD Maximum nozzle height H
max
1)
100 to 150 mm (4 to 6 in) 1 450 mm (58 in)
≥ 150 mm (6 in) 2 200 mm (88 in)
1) In case of longer nozzles, a reduction of the measuring performance is to be expected.
Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Endress+Hauser for applications with nozzles that are higher than indicated in
the table.
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 55 mm
• Maximum permissible torque: 50 Nm (36 lbf ft)
Container with heat
insulation
A0032207
If process temperatures are high, the device should be included in the usual container insulation
system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The
insulation should not be higher than the neck of the device (1).