Mounting Micropilot FMR67B PROFINET with Ethernet-APL
22 Endress+Hauser
5.3.9 Changing the installation position of the display module
The installation position of the display can be changed in the case of the dual
compartment housing, L-form.
A0048401
L
WARNING
Supply voltage switched on!
Risk of electric shock and/or explosion!
Switch off the supply voltage before opening the measuring device.
1 → 2 → 3 →
0.7 Nm
4 mm
2 x
1.
2.
2.
1.
A0046831 A0046832 A0046833
If fitted: release the screw of
the cover lock for the display
cover using the Allen key.
Unscrew the display cover and
check the cover seal.
Press the release mechanism,
remove the display module.
4 → 5 → 6 →
0.7 Nm
4 mm
2 x
1.
2.
A0046834 A0046923 A0046924
Release the connection.
If fitted: release the screw of
the cover lock for the
connection compartment cover
using the Allen key.
Unscrew the connection
compartment cover, check the
cover seal. Screw this cover
onto the electronics
compartment instead of the
display cover. If fitted: tighten
the screw of the cover lock
using the Allen key