6.3 Key functions
Measurement
Measured value display
Return to measuring mode from
any position
Calibration
Activate calibration mode
Calibration menu display
Diagnostics
Call up fault and maintenance
messages
Retrieve information and statistics
Call up service routine including
simulation, internal data and
instrument check
Configuration
Configuration menu display
(setting the instrument for new
measuring and control tasks)
Return to next higher menu level
Increment number displayed
in inverse video
Select menu line by moving
inverse-video bar
Return to previous screen
Decrement number displayed
in inverse video
Select menu line by moving
inverse-video bar
Move to next screen
Select editing point with multi-digit
numbers
Enter
Accept value or parameter during
configuration
Select inverse-video menu line
6.4 Operating concept
The function of the Mycom CLM 152
measuring transmitter are divided into four
main groups:
Measurement
Calibration
Diagnostics
Configuration
The groups are called by pressing the
appropriate keys (see Chapter 6.3). The main
groups contain functions that are combined
into sub-groups. Some of these sub-groups
may also be subdivided.
The sub-groups are displayed as menus and
you can select them by pressing and
(inverse video line). The menu may also
contain more options than are displayable on
one screen page. This is indicated by a small
arrow at the left-hand border of the window.
Confirm your selection by pressing E.
Note:
You fill find an overview of the
Mycom menu structure on the rear
fold-out pages of this manual.
Select options or the configuration set-up
within the sub-groups by using the menu
selection (see above) or by editing a digit.
To do this, select the digit by pressing and
set the value required by pressing and .
Repeat this process for all the other digits.
Confirm your setting by pressing E.
The setting limits for digits are displayed in
the penultimate line of the display. Settings
outside the specified limits are not permitted.
After you confirm, the request appears for the
next parameter.
When all the parameters have been
requested in a sub-group, the sub-group
menu re-appears.
Press the Param key to return to the next
higher group menu.
MEAS
CAL
DIAG
PARAM
Operation Mycom CLM 152
28 Endress+Hauser