Installation Nivector FTI26
14 Endress+Hauser
A
!B
!C
A
C - B
<
=
1
A0036363
 8 Installation with Tri-Clamp, which can be ordered as an accessory, and with NA Connect adapter
provided by customer
A Distance between Tri-Clamp and NA Connect adapter
B Diameter of Nivector
C Diameter of NA Connect adapter
Installation with protector
Protection of point level switch against damage by particularly abrasive or coarse product
Outflow protection in silo for functional testing when silo is full
≥20 (0.8)
G 1½"
A0036361
 9 Installation with protector, can be ordered as an accessory
Take account of metallic or non-metallic vessels in accordance with EMC guidelines, see
Technical Information TI01384F.
5.2.3 Protection cover for hazardous areas
L
WARNING
Damage to the device from impact.
The protection cover must be fitted before the device is put into operation.