2.1 Probes and sensors
Table 2.1 lists the sensors most frequently used with the Prolevel FMC 661 transmitter.
In addition to those listed, all probes which can be used with an EC 17 Z, EC 37 Z or
EC 47 Z electronic insert can be connected to the transmitter. Installation hints can be
taken from the appropriate Technical Information Sheet.
Sensor constantsDeltapilot S hydrostatic pressure sensors and EC 37 Z/47 Z inserts are supplied with the
sensor constants zero frequency »fo« and sensitivity »∆f« or »S«, see Fig. 2.2. For
Deltapilot S sensors the constants depend on the measuring range, see Table 2.2. Note
these constants and enter them into fields V3H5 and V3H6 during commissioning,
Section 4.1. This dispenses with the need for a recalibration of the transmitter on
replacement of the sensor or insert.
Principle
Channel 1 Channel 2
Probe TI sheet Insert Probe TI sheet Insert
Capacitance DC 11 TI 169F
DC 16 TI 096F
DC 21 TI 208F
DC 26 TI 209F
11 322 Z E 11.81.03
11 500 Z TI 161F
21 211 E 10.73.18
Multicap TE, TA, E, A
TI 239, 240, 242, 243
EC 37 Z
EC 47 Z
DC 11 TI 169F
DC 16 TI 096F
DC 21 TI 208F
DC 26 TI 209F
11 450 (Z/St) TI 197
11 961 (Z) E 04.77.04
21 262 (Z/St) TI 227
21 265 (Z/St) TI 195
Multicap TE, TA, E, A
EC 17 Z
EC 16 Z
FEC 22
Hydrostatic
pressure
Deltapilot S TI 257
DB 50, 50 L, 51, 52, 53
FEB17
FEB 17P
Not suitable
Vibration Not suitable Liquiphant
DL 17 Z 013154-0008
FDL 30/31/35/36 TI 185F
Soliphant
DM 90 Z
…
92 Z TI 124F
BA042
EL 17 Z
EM 17 Z
Table 2.1:
Selection of probes suitable for
use with the Prolevel FMC 661
1 3 6542
+
I
II
CA (pF)
C(S)(pF)
17
d4
d4/z4
7
18
d2
d2/z2
8
FMC480Z
FMC470Z
FMC671/672/676/677Z
HAA420Z
1MHz
EC 47Z
Ex
0,6526,805S
III
f
o
475,3 57,2
EC10015EP8
BA142_10
sensor constants
Fig. 2.2:
Location of sensor constants on
EC 37 Z/47 Z electronic insert
and Deltapilot S DB 4x housing
Cell
type
Electronic insert FEB 17/FEB 17 P
Range f
0
∆f
Range f
0
∆f
0.1 bar BA 0…100 mbar 200 10 DA -100…100 mbar 200 5
0.4 bar BB 0…400 mbar 200 2.5 DB -400…400 mbar 200 1.25
1.2 bar BC 0…1200 mbar 200 0.833 DC -900…1200 mbar 200 0.476
4.0 bar BD 0…4000 mbar 200 0.25 DD -900…4000 mbar 200 0.204
Table 2.2:
Measuring ranges and sensor
constants of
Deltapilot S DB 5x
Prolevel FMC 661 Chapter 2: Installation
Endress+Hauser 13