EasyManua.ls Logo

Endress+Hauser Proline 200 - 5.2.6 device plug pin assignment

Endress+Hauser Proline 200
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection Flowmeter Proline 200 PROFINET with Ethernet-APL
20 Endress+Hauser
Connecting cable (standard, reinforced)
+
+
2
1
1
2
1 2 3 4
1 2 3 4
GNYEWHBN
A0033476
 3 Terminals for connection compartment in the transmitter wall holder and the sensor connection
housing
1 Terminals for connecting cable
2 Grounding via the cable strain relief
Terminal number Assignment Cable color
Connecting cable
1 Supply voltage Brown
2 Grounding White
3 RS485 (+) Yellow
4 RS485 (–) Green
5.2.6 device plug pin assignment
2
3
1
4
Pin Assignment Coding Plug/
socket
1 - APL signal - A Socket
2 + APL signal +
3 Cable shield
1
4 Not assigned
Metal plug
housing
Cable shield
1
If a cable shield is used