3 Installation PROline Promag 10
18 Endress+Hauser
Flow rate characteristic values - Promag W (US units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm] [inch]
Min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
Current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
1" 25 2.5...80 gal/min 18 gal/min 0.20 gal 0.25 gal/min
1 1/4" 32 4 ...130 gal/min 30 gal/min 0.20 gal 0.50 gal/min
1 1/2" 40 7 ...190 gal/min 50 gal/min 0.50 gal 0.75 gal/min
2" 50 10 ...300 gal/min 75 gal/min 0.50 gal 1.25 gal/min
2 1/2" 65 16 ...500 gal/min 130 gal/min 1 gal 2.0 gal/min
3" 80 24 ...800 gal/min 200 gal/min 2 gal 2.5 gal/min
4" 100 40 ...1250 gal/min 300 gal/min 2 gal 4.0 gal/min
5" 125 60 ...1950 gal/min 450 gal/min 5 gal 7.0 gal/min
6" 150 90 ...2650 gal/min 600 gal/min 5 gal 12 gal/min
8" 200 155 ...4850 gal/min 1200 gal/min 10 gal 15 gal/min
10" 250 250 ...7500 gal/min 1500 gal/min 15 gal 30 gal/min
12" 300 350 ...10600 gal/min 2400 gal/min 25 gal 45 gal/min
14" 350 500 ...15000 gal/min 3600 gal/min 30 gal 60 gal/min
16" 400 600 ...19000 gal/min 4800 gal/min 50 gal 60 gal/min
18" 450 800 ...24000 gal/min 6000 gal/min 50 gal 90 gal/min
20" 500 1000 ...30000 gal/min 7500 gal/min 75 gal 120 gal/min
24" 600 1400 ...44000 gal/min 10500 gal/min 100 gal 180 gal/min