EasyManua.ls Logo

Endress+Hauser Proline Promag 10 - Page 18

Endress+Hauser Proline Promag 10
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Installation PROline Promag 10
18 Endress+Hauser
Flow rate characteristic values - Promag W (US units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm] [inch]
Min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
Current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
1" 25 2.5...80 gal/min 18 gal/min 0.20 gal 0.25 gal/min
1 1/4" 32 4 ...130 gal/min 30 gal/min 0.20 gal 0.50 gal/min
1 1/2" 40 7 ...190 gal/min 50 gal/min 0.50 gal 0.75 gal/min
2" 50 10 ...300 gal/min 75 gal/min 0.50 gal 1.25 gal/min
2 1/2" 65 16 ...500 gal/min 130 gal/min 1 gal 2.0 gal/min
3" 80 24 ...800 gal/min 200 gal/min 2 gal 2.5 gal/min
4" 100 40 ...1250 gal/min 300 gal/min 2 gal 4.0 gal/min
5" 125 60 ...1950 gal/min 450 gal/min 5 gal 7.0 gal/min
6" 150 90 ...2650 gal/min 600 gal/min 5 gal 12 gal/min
8" 200 155 ...4850 gal/min 1200 gal/min 10 gal 15 gal/min
10" 250 250 ...7500 gal/min 1500 gal/min 15 gal 30 gal/min
12" 300 350 ...10600 gal/min 2400 gal/min 25 gal 45 gal/min
14" 350 500 ...15000 gal/min 3600 gal/min 30 gal 60 gal/min
16" 400 600 ...19000 gal/min 4800 gal/min 50 gal 60 gal/min
18" 450 800 ...24000 gal/min 6000 gal/min 50 gal 90 gal/min
20" 500 1000 ...30000 gal/min 7500 gal/min 75 gal 120 gal/min
24" 600 1400 ...44000 gal/min 10500 gal/min 100 gal 180 gal/min