PROline Promag 10 10 Technical data
Endress+Hauser 81
Process
Medium temperature
range
The permissible fluid temperature depends on the lining of the measuring tube:
Promag W:
0...+80 °C for hard rubber (DN 65...600)
–20...+60 °C for polyurethane (DN 25...600)
Promag P:
–40...+130 °C for PTFE (DN 25...300), for restrictions → refer to diagrams
Fig. 43: Compact versions, Promag P
T
A
= Ambient temperature, T
F
= Medium temperature
Fig. 44: Remote versions, Promag P
T
A
= Ambient temperature, T
F
= Medium temperature
Promag H
Sensor:
• DN 2...25: –20...+150 °C
• DN 40...100: –20...+150 °C
Seal:
• EPDM: –20...+130 °C
• Viton: –20...+150 °C
• Kalrez: –20...+150 °C
Conductivity Minimum conductivity: ≥ 50 µS/cm
Note that in the case of the remote version, the requisite conductivity is also influenced
by the length of the connecting cable → Page 21
0
0
-20 20
20
40
60
T
A
[°C]
40 60 80
T
F
[°C]
100 120 140 160 180
PTFE
Esc
E
-
+
F06-10Pxxxxx-05-xx-xx-xx-000
0
0
-20 20
20
40
60
T
A
[°C]
40 60 80
T
F
[°C]
100 120 140 160 180
PTFE
F06-10Pxxxxx-05-xx-xx-xx-000