EasyManua.ls Logo

Endress+Hauser Proline Promag 10 - Page 82

Endress+Hauser Proline Promag 10
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Technical data PROline Promag 10
82 Endress+Hauser
Medium pressure range
(nominal pressure)
Promag W
Promag P
Promag H
The permissible nominal pressure depends on the process connection and seal:
40 bar: flange, weld nipple (with O-ring seal)
16 bar: all other process connections
Pressure tightness
(measuring tube lining)
DIN 2501 PN 10 (DN 200...600), PN 16 (DN 65...150), PN 40 (DN 25...50)
ANSI B16.5 Class 150 (1...24")
JIS B2238 10K (DN 65...600), 20K (DN 25...50)
DIN 2501 PN 10 (DN 200...300), PN 16 (DN 65...150), PN 40 (DN 25...150)
ANSI B16.5 Class 150 (1...12")
JIS B2238 10K (DN 65...300), 20K (DN 25...50)
Promag W
nominal diameter
Measuring
tube lining
Pressure tightness, measuring tube lining
Limit values for absolute pressure [mbar] with different fluid
temperatures
[mm] [inch] 25 °C 60°C 80 °C 100 °C 130 °C 150 °C 180 °C
25...600 1...24" Polyurethane 0 0 −−−−−
65...600 1...24" Hard rubber 0 0 0 −−−−
Promag P
nominal
diameter
Measuring tube
lining
Pressure tightness, measuring tube lining
Limit values for absolute pressure [mbar] with different fluid
temperatures
[mm] [inch] 25 °C 80 °C 100 °C 130 °C
25 1" PTFE 0 0 0 100
32 PTFE 0 0 0 100
40 1 1/2" PTFE 0 0 0 100
50 2" PTFE 0 0 0 100
65 PTFE 0 * 40 130
80 3" PTFE 0 * 40 130
100 4" PTFE 0 * 135 170
125 PTFE 135 * 240 385
150 6" PTFE 135 * 240 385
200 8" PTFE 200 * 290 410
250 10" PTFE 330 * 400 530
300 12" PTFE 400 * 500 630
* No value can be specified.
Promag H
nominal diameter
Measuring tube
lining
Pressure tightness, measuring tube lining
Limit values for absolute pressure [mbar] with different
fluid temperatures
[mm] [inch] 25 °C 80 °C 100 °C 130 °C 150 °C 180 °C
2 ...1001/12...4" PFA 000000

Table of Contents