10 Technical data PROline Promag 10
86 Endress+Hauser
Promag H
Transmitter housing:
• Compact housing: powder-coated die-cast aluminum
• Remote version housing: powder-coated die-cast aluminium
Sensor housing: 1.4301
Wall mounting kit (holding plate): 1.4301
Measuring tube: stainless steel 1.4301 or 1.4306/304L
Flanges: connections generally made of 1.4404/316L
Ground rings: 1.4435/316L, Alloy C-22
Electrodes:
• Standard: 1.4435
• Optional: Alloy C-22
Seals:
• DN 2...25: O-ring (EPDM, Viton, Kalrez) or moulded seal (EPDM, silicone, Viton)
• DN 40...100: moulded seal (EPDM, silicone)
Material load diagram The material load diagrams (pressure-temperature graphs) for the process connections
are to be found in the following documents:
• Technical Information “Promag 10 W” (TI 093D/06/en)
• Technical Information “Promag 10 P” (TI 094D/06/en)
• Technical Information “Promag 10 H” (TI 095D/06/en)
Fitted electrodes Promag W:
Measuring electrodes, reference electrodes and Empty Pipe Detection electrodes
Available as standard with: 1.4435/316L, Alloy C-22
Promag P:
Measuring electrodes, reference electrodes and Empty Pipe Detection electrodes
Available as standard with: 1.4435/316L, Alloy C-22
Promag H:
Measuring electrodes and Empty Pipe Detection electrodes
• Available as standard with: 1.4435/316L, Alloy C-22
• DN 2...4: without Empty Pipe Detection electrode
Process connection Promag W:
Flange connection: DIN (dimensions to DIN 2501), ANSI, JIS
Promag P:
Flange connection: DIN (dimensions to DIN 2501), ANSI, JIS
Promag H:
• With O-ring: flange (DIN, ANSI, JIS), external thread (ISO 228/DIN299)
• With moulded seal: weld socket (DIN 11850, ODT), Tri-Clamp,
threaded joint (DIN 11851, DIN 11864-1, SMS1145), flange DIN 11864-2
Surface roughness • Measuring tube lining with PFA: ≤ 0.3 µm (Promag H)
• Electrodes:
1.4435/316L, Alloy C-22: ≤ 0.4 µm
• Promag H process connection: ≤ 0.8 µm