EasyManua.ls Logo

Endress+Hauser Proline Promag 10 - System Configuration

Endress+Hauser Proline Promag 10
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROline Promag 10 11 Description of Device Functions
Endress+Hauser 93
11.2 Group SYSTEM UNITS
Function description SYSTEM UNITS
Use this function group to select the unit for the measured variable.
UNIT VOLUME FLOW Use this function to select the unit for displaying the volume flow.
The unit you select here is also valid for:
Volume flow display
Current output
Switch points (limit value for volume flow, flow direction)
Low flow cut off
Options:
Metric:
Cubic centimetre
cm
3
/s; cm
3
/min; cm
3
/h; cm
3
/day
Cubic decimetre
dm
3
/s; dm
3
/min; dm
3
/h; dm
3
/day
Cubic metre
m
3
/s; m
3
/min; m
3
/h; m
3
/day
Millilitre
ml/s; ml/min; ml/h; ml/day
Litre
l/s; l/min; l/h; l/day
Hectolitre
hl/s; hl/min; hl/h; hl/day
Megalitre
Ml/s; Ml/min; Ml/h; Ml/day
US:
Cubic centimeter
cc/s; cc/min; cc/h; cc/day
Acre foot
af/s; af/min; af/h; af/day
Cubic foot
ft
3
/s; ft
3
/min; ft
3
/h; ft
3
/day
Fluid ounce
oz f/s; oz f/min; oz f/h; oz f/day
Gallon
gal/s; gal/min; gal/h; gal/day
Million gallons
Mgal/s; Mgal/min; Mgal/h; Mgal/day
Barrel (normal fluids: 31.5 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Barrel (beer: 31.0 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Barrel (petrochemicals: 42.0 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Barrel (filling tanks: 55.0 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Imperial
Gallon
gal/s; gal/min; gal/h; gal/day
Mega gallon
Mgal/s; Mgal/min; Mgal/h; Mgal/day
Barrel (beer: 36.0 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Barrel (petrochemicals: 34.97 gal/bbl)
bbl/s; bbl/min; bbl/h; bbl/day
Factory setting:
Depends on nominal diameter and country
(dm
3
/min...m
3
/h or US-gal/min),
corresponding to the full scale value unit (see Page 116 ff.) factory setting.
UNIT VOLUME Use this function to select the unit for displaying the volume.
The unit you select here is also valid for:
Totalizer status display
Totalizer unit
Pulse value (e.g. m
3
/p)
Options:
Metric
cm
3
; dm
3
; m
3
; ml; l; hl; Ml
US
cc; af; ft
3
; oz f; gal; Mgal; bbl (normal fluids); bbl (beer);
bbl (petrochemicals)
bbl (filling tanks)
Imperial
gal; Mgal; bbl (beer); bbl (petrochemicals)
Factory setting:
Depends on nominal diameter and country (dm
3
...m
3
or US-gal),
corresponding to the totalizer unit (see Page 116 ff.) factory setting.