5Operation PROline Promag 53
62 Endress+Hauser
Display (operation mode)
The display area consists of three lines in all; this is where measured values are dis-
played, and/or status variables (direction of flow, partially filled pipe, bargraph, etc.).
You can change the assignment of display lines to variables at will in order to customize
the display to suit your needs and preferences ( see the “Description of Device
Functions” manual).
Multiplex mode:
A maximum of two different display variables can be assigned to each line.
Variables multiplexed in this way alternate every 10 seconds on the display.
Error messages:
The display modes for system and process error messages are described in detail on
Page 67
Fig. 42: Typical display for normal operating mode (HOME position)
1 Main line shows primary measured values, e.g. volume flow in [gal/min, l/s].
2 Supplementary line shows supplementary measured variables, e.g. totalizer No. 3 in [gallons / m
3
]
3 Information line shows additional information on the measured variables, e.g. bar graph of the limit value
reached by the volume flow.
4 Info icons” field: Icons representing additional information on the measured values are shown in this
field. See Page 63 for a full list of the icons and their meanings.
5 “Measured values” field: The current measured values appear in this field.
6 “Unit of measure” field: The units of measure and time defined for the current measured values appear
in this field.
Additional display functions
Depending on the order options, the local display has different display functions:
Device without batching software:
From HOME position, use the +/- keys to open an “Info Menu” containing the following
information:
Totalizers (including overflow)
Actual values or states of the configured inputs/outputs
Device TAG number (user-definable)
OS Scan of individual values within the Info Menu
X (Esc key) Back to HOME position
Device with batching software:
On measuring instruments with installed batching software (F-CHIP, see Page 97) and
a suitably configured display line, you can carry out filling processes directly using the
local display. You will find a detailed description on Page 64.