EasyManua.ls Logo

Endress+Hauser PROline promag 53 - 4.5 Degree of Protection

Endress+Hauser PROline promag 53
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5Operation PROline Promag 53
64 Endress+Hauser
Controlling the batching processes using the local display
With measuring instruments with suitable software, you can carry out batching proc-
esses directly using the local display. Therefore, the Promag 53 can be fully deployed
in the field as a “batch controller”.
Procedure:
1. Configure all the required batching functions and assign the lower display info line
(= BATCHING KEYS) using the “Batch” Quick Setup menu or use the function
matrix. The following “softkeys” then appear on the bottom line of the local display
(Fig. 43):
START = left display key (–)
PRESET = middle display key (+)
MATRIX = right display key (E)
2. Press the “PRESET (+)” key. Various batching process functions requiring configu-
ration will now appear on the display:
3. After exiting the PRESET menu, you can now start the batching process by press-
ing “START (–)”. New softkeys (STOP / HOLD or GO ON) now appear on the display.
You can use these to interrupt, continue or stop the batching process at any time
(Fig. 43):
STOP (–) Stop batching process
HOLD (+) Interrupts batching process (softkey changes to “GO ON”)
GO ON (+) Continues batching process (softkey changes to “HOLD”)
After the batch quantity is reached, the “START” or “PRESET” softkeys reappear on
the display.
Fig. 43: Controlling batching processes using the local display (softkeys)
“PRESET” Initial settings for the batching process
No. Function Settings
7200 BATCH SELECTOR
OS Selection of the batching liquid
(BATCH #1...6)
7203 BATCH QUANTITY Displays the appropriate batching quantity (changes are
only possible after entering the enabling code).
7265 RESET TOTAL
BATCH SUM/COUNTER
Resets the batching quantity counter or the total batching
quantity to “0”.
STOP
GO ON MATRIX
+2.5 l
0.0 l
E
+2.5 l
0.0 l
0.0 l
+
-
+2.5 l
0.0 l
START
PRESET MATRIX
STOP
HOLD MATRIX
F06-x3xxxxxx-07-xx-xx-xx-005