5Operation PROline Promag 53
78 Endress+Hauser
4
0 not assigned –
1 not assigned –
2 not assigned –
3 not assigned –
4 261 No data reception between amplifier and I/O board
5 not assigned –
6 not assigned –
7 not assigned –
5
0 321 Coil current of the sensor is outside the tolerance.
1 not assigned –
2 not assigned –
3 not assigned –
4 not assigned –
5 not assigned –
6 not assigned –
7 339
Flow buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
6
0 340
1 341
2 342
3 343
Frequency buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
4 344
5 345
6 346
7 347
Pulse buffer:
The temporarily buffered flow portions (measuring mode for pul-
sating flow) could not be cleared or output within 60 seconds.
7
0 348
1 349
2 350
3 351
Current output: flow is out of range.
4 352
5 353
6 354
7 355
Frequency output: flow is out of range.
8
0 356
1 357
2 358
3 359
Pulse output: the pulse output frequency is out of range.
4 360
5 361
6 362
7 not assigned –
Byte Bit Error No. Short error description ( → Page 100 )