Proline Promag 53 NEPSI Zone 1, Zone 21 0
Endress+Hauser 7
Temperature table remote
version
Sensor
Max. medium temperature [°C] for T1
~ T6 in relation to the maximum ambient temperature T
a
1)
with polyurethane lining;
2)
with hard rubber lining
1)
with PFA lining;
2)
with PTFE lining;
3)
versions in IP 68 are limited to 130 °C.
The minimum ambient temperature is –20 °C.
A version for ambient temperatures up to –40 °C is optionally available.
Transmitter
The transmitter of the remote version has the temperature class T6 when installing into the Ex d housing up
to an ambient temperature of T
a
= 60 °C.
The maximum ambient temperature range is –20 to +60 °C.
A version for ambient temperatures up to –40 °C is optionally available.
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promag 5*W**-************
25 to 1200
1)
+50 °C 50 50 50 50 50 50
50 to 2000
2)
+60 °C 80 80 80 80 80 80
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promag 5*P**-************
25 to 200
1)
+50 °C 80 95 130
150
3)
150
3)
150
3)
15 to 600
2)
130 130 130
25 to 200
1)
+60 °C 80 95 130 130 130 130
15 to 600
2)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promag 5*H**-************
2 to 150 +50 °C 80 95 130 150 150 150
2 to 25
+60 °C
80 95 130 130 130 130
40 to 150 80 95 130 150 150 150