General warnings
#
Installation, connection to the electricity supply, commissioning and maintenance of
the devices must be carried out by qualified specialists trained to work on Ex-rated
devices.
Compliance with national regulations relating to the installation of devices in poten-
tially explosive atmospheres is mandatory, if such regulations exist.
Open the device only when it is de-energized (and after a delay of at least 10 minutes
following shutdown of the power supply).
The housing of the Ex-rated transmitter can be turned in 90° steps. Whereas the non-
Ex version has a bayonet adapter, however, the Ex version has a thread. Recesses for
centering the worm screw are provided to prevent inadvertent movement of the trans-
mitter housing.
It is permissible to turn the transmitter housing through a maximum of 180° during
operation (in either direction), without compromising explosion protection.
After turning the housing the worm screw must be fastened again.
The screw cap has to be removed before the local display can be turned, and this
must be done with the device de-energized (and after a delay of at least 10 minutes
following shutdown of the power supply).