Promag 53 PROFIBUS DP/PA Technical data
Endress+Hauser 165
• AS 4087
– PN 16 (DN 50 / 2")
Promag W
• EN 1092-1 (DIN 2501)
– PN 6 (DN 350 to 2000 / 14 to 84")
– PN 10 (DN 200 to 2000 / 8 to 84")
– PN 16 (DN 65 to 2000 / 3 to 84")
– PN 25 (DN 200 to 1000 / 8 to 40")
– PN 40 (DN 25 to 150 / 1 to 6")
• ASME B 16.5
– Class 150 (1 to 24")
– Class 300 (1 to 6")
• AWWA
– Class D (28 to 78")
• JIS B2220
– 10K (DN 50 to 300 / 2 to 12")
– 20K (DN 25 to 300 / 1 to 12")
• AS 2129
– Table E (DN 80 / 3", 100 / 4", 150 to 1200 / 6 to 48")
• AS 4087
– PN 16 (DN 80 / 3", 100 / 4", 150 to 1200 / 6 to 48")
Pressure tightness (measuring tube lining)
Promag E (Measuring tube lining: PTFE)
Nominal diameter Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid temperatures
[mm] [inch]
25 °C 80 °C 100 °C 110 °C
77 °F 176 °F 212 °F 230 °F
[mbar] [psi] [mbar] [psi] [mbar] [psi]
15½"0000001001.45
25 1" 0 0 0 0 0 0 100 1.45
32–0000001001.45
40 1 ½" 0 0 0 0 0 0 100 1.45
50 2" 0 0 0 0 0 0 100 1.45
65 – 0 0 * * 40 0.58 130 1.89
80 3" 0 0 * * 40 0.58 130 1.89
100 4" 0 0 * * 135 1.96 170 2.47
125 – 135 1.96 * * 240 3.48 385 5.58
150 6" 135 1.96 * * 240 3.48 385 5.58
200 8" 200 2.90 * * 290 4.21 410 5.95
250 10" 330 4.79 * * 400 5.80 530 7.69
300 12" 400 5.80 * * 500 7.25 630 9.14
350 14" 470 6.82 * * 600 8.70 730 10.59
400 16" 540 7.83 * * 670 9.72 800 11.60
450 18" Partial vacuum is impermissible!
500 20"
600 24"
* No value can be quoted.