EasyManua.ls Logo

Endress+Hauser PROline promag 53 - Pressure Tightness (Measuring Tube Lining); Promag E (Measuring Tube Lining: PTFE)

Endress+Hauser PROline promag 53
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Promag 53 PROFIBUS DP/PA Technical data
Endress+Hauser 165
AS 4087
PN 16 (DN 50 / 2")
Promag W
EN 1092-1 (DIN 2501)
PN 6 (DN 350 to 2000 / 14 to 84")
PN 10 (DN 200 to 2000 / 8 to 84")
PN 16 (DN 65 to 2000 / 3 to 84")
PN 25 (DN 200 to 1000 / 8 to 40")
PN 40 (DN 25 to 150 / 1 to 6")
ASME B 16.5
Class 150 (1 to 24")
Class 300 (1 to 6")
AWWA
Class D (28 to 78")
JIS B2220
10K (DN 50 to 300 / 2 to 12")
20K (DN 25 to 300 / 1 to 12")
AS 2129
Table E (DN 80 / 3", 100 / 4", 150 to 1200 / 6 to 48")
AS 4087
PN 16 (DN 80 / 3", 100 / 4", 150 to 1200 / 6 to 48")
Pressure tightness (measuring tube lining)
Promag E (Measuring tube lining: PTFE)
Nominal diameter Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid temperatures
[mm] [inch]
25 °C 80 °C 100 °C 110 °C
77 °F 176 °F 212 °F 230 °F
[mbar] [psi] [mbar] [psi] [mbar] [psi]
15½"0000001001.45
25 1" 0 0 0 0 0 0 100 1.45
32–0000001001.45
40 1 ½" 0 0 0 0 0 0 100 1.45
50 2" 0 0 0 0 0 0 100 1.45
65 0 0 * * 40 0.58 130 1.89
80 3" 0 0 * * 40 0.58 130 1.89
100 4" 0 0 * * 135 1.96 170 2.47
125 135 1.96 * * 240 3.48 385 5.58
150 6" 135 1.96 * * 240 3.48 385 5.58
200 8" 200 2.90 * * 290 4.21 410 5.95
250 10" 330 4.79 * * 400 5.80 530 7.69
300 12" 400 5.80 * * 500 7.25 630 9.14
350 14" 470 6.82 * * 600 8.70 730 10.59
400 16" 540 7.83 * * 670 9.72 800 11.60
450 18" Partial vacuum is impermissible!
500 20"
600 24"
* No value can be quoted.

Table of Contents

Other manuals for Endress+Hauser PROline promag 53

Related product manuals