Promag 53 PROFIBUS DP/PA Technical data
Endress+Hauser 181
Promag L
Flange connection:
• EN 1092-1 (DIN 2501)
–DN 300 (12") = form A
–DN 350 (14") = form B
• ASME B16.5
• AWWA C207
•AS
Promag P/W
Flange connections:
• EN 1092-1 (DIN 2501)
–DN 300 (12") = form A
–DN 350 (14") = flat face
– DN 65 PN 16 and DN 600 PN 16 exclusively according to EN 1092-1
•ASME
• AWWA (Promag W only)
•JIS
•AS
Surface roughness
All data relate to parts in contact with fluid.
•Liner PFA: 0.4 μm (15 μin)
• Electrodes: 0.3 to 0.5 μm (12 to 20 μin)
• Process connection made of stainless-steel (Promag H):
–with O-ring seal: 1.6 μm (63 μin)
– with aseptic gasket seal: 0.8 μm (31.5 μin)
–optional: 0.38 μm (15 μin)
10.1.11 Human interface
Display elements
• Liquid crystal display: illuminated, four lines with 16 characters per line
• Selectable display of different measured values and status variables
• 3 totalizers
• At ambient temperatures below -20 C (–15 °F) the readability of the display may be
impaired.
Operating elements
• Local operation with three optical keys (
S
/
O
/
F
)
• Application-specific Quick Setup menus for straightforward commissioning
Language groups
Language groups available for operation in different countries:
• Western Europe and America (WEA):
English, German, Spanish, Italian, French, Dutch and Portuguese
• Eastern Europe and Scandinavia (EES):
English, Russian, Polish, Norwegian, Finnish, Swedish and Czech.
• South and east Asia (SEA):
English, Japanese, Indonesian
• China (CN):
English, Chinese