Promag 53 PROFIBUS DP/PA Installation
Endress+Hauser 43
3.3.8 Installing the wall-mount housing
There are various ways of installing the wall-mount housing:
• Mounted directly on the wall
• Panel mounting (with separate mounting kit, accessories) → 44
• Pipe mounting (with separate mounting kit, accessories) → 44
"
Caution!
• Make sure that the permitted ambient temperature range is observed (see nameplate or
→ 160). Install the device in a shady location. Avoid direct sunlight.
• Always install the wall-mount housing in such a way that the cable entries are pointing
down.
Mounted directly on the wall
1. Drill the holes as illustrated.
2. Remove the cover of the connection compartment (a).
3. Push the two securing screws (b) through the appropriate bores (c) in the housing.
– Securing screws (M6): max. Ø 6.5 mm (0.24")
– Screw head: max. Ø 10.5 mm (0.4")
4. Secure the transmitter housing to the wall as indicated.
5. Screw the cover of the connection compartment (a) firmly onto the housing.
a0001130
Fig. 27: Mounted directly on the wall
a
b
c
90 (3.54)
35 (1.38)
192 (7.56)
81.5 (3.2)