Installation Promag 53 PROFIBUS DP/PA
44 Endress+Hauser
Panel mounting
1. Prepare the opening in the panel as illustrated.
2. Slide the housing into the opening in the panel from the front.
3. Screw the fasteners onto the wall-mount housing.
4. Place the threaded rods in the fasteners and screw them down until
the housing is seated tightly against the panel wall. Afterwards, tighten the locking
nuts.
Additional support is not necessary.
a0001131
Fig. 28: Panel mounting (wall-mount housing)
Pipe mounting
The assembly should be performed by following the instructions in the following diagram.
"
Caution!
If the device is mounted to a warm pipe, make sure that the housing temperature does not
exceed +60 °C (+140 °F), which is the maximum permissible temperature.
a0001132
Fig. 29: Pipe mounting (wall-mount housing)
245 (9.65)
~110 (~4.33)
210 (8.27)
+0.5 (+0.019)
–0.5 (–0.019)
+0.5 (+0.019)
–0.5 (–0.019)
Ø 20…70
(Ø 0.79…2.75)
~ ~ 6.1)155 (