Operation Promag 53 PROFIBUS DP/PA
68 Endress+Hauser
5.2.2 Display (operating mode)
The display area consists of three lines in all; this is where measured values are displayed,
and/or status variables (direction of flow, bar graph, etc.). You can change the assignment
of display lines to different variables to suit your needs and preferences ( see the
"Description of Device Functions" manual).
Multiplex mode:
A maximum of two different display variables can be assigned to each line. Variables
multiplexed in this way alternate every 10 seconds on the display.
Error messages:
Display and presentation of system/process errors 73
a0004755
Fig. 44: Typical display for normal operating mode (HOME position)
1 Main display line: shows primary measured values, e.g. mass flow in [kg/h]
2 Additional line: shows measured variables and status variables, e.g. totalizer No. 3 in [t]
3 Information line: shows additional information on the measured variables and status variables,
e.g. bar graph display of the full scale value achieved by the mass flow
4 "Info icons" field: icons representing additional information on the measured values are shown in this field. 69
5 "Measured values" field: the current measured values appear in this field
6 "Unit of measure" field: the units of measure and time defined for the current measured values appear in this field
5.2.3 Additional display functions
Depending on the order option (F-CHIP 126), the local display has different display
functions:
Device without batching software:
From HOME position, use the
OS
keys to open an "Info Menu" containing the following
information:
Totalizer (including overflow)
Actual values or states of the configured inputs/outputs
Device TAG number (user-definable)
OS
Scan of individual values within the Info Menu
X
(Esc key) Back to HOME position
Device with batching software:
On measuring devices with installed batching software (F-Chip 126) and a suitably
configured display line, you can carry out filling processes directly using the local display.
You will find a detailed description on 70.
1
45
6
2
3
+24.502
+1863.97
x
x
y
y
–50
+50
%
v
v
TOT
OK
3