Proline Promag 50H, 53H
Endress+Hauser 41
Process connections with aseptic gasket seal, DN 2 to 25 (¹₁₂ to 1")
Hose adapter
1.4404 (316L)
Sensor DN Fits to inside
diameter
di L H × B
5*H**-M/N/P*********** [mm] [mm] [mm] [mm] [mm]
A0005562
2 to 8 13 10.0 49 62 × 42
15 16 12.6 49 62 × 42
15 19 16.0 49 62 × 42
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
1.6 m
Adhesive sleeve
PVC
Sensor DN Fits to pipe di G L H × B
5*H**-R/S*********** [mm] [mm] /[inch] [mm] [mm] [mm] [mm]
A0005566
2 to 8 ½" [inch] 21.5 27.3 38.5 62 × 42
2 to 8 20 × 2 [mm]
(DIN 8062)
20.2 27.0 38.5 62 × 42
15 20 × 2 [mm]
(DIN 8062)
20.2 27.0 28.0 62 × 42
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
1.6 m
The requisite ground rings can be ordered as accessories
(Order No. DK5HR-****).
Welding nipple according to
EN 10375 (DIN 1180)
1.4404 (316L)
Sensor DN Fits to piping di G L H × B
5*H**-U*********** [mm] EN 10357
(DIN 11850)
[mm] [mm] [mm] [mm]
A0003870
2 to 8 14 × 2 10 14 23.3 62 × 42
15 20 × 2 16 20 23.3 62 × 42
25 (DIN) 30 × 2 26 30 23.3 72 × 55
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
0.8 m
If pigs are used for cleaning, it is essential to take the inside diameters
of measuring tube and process connection (di) into account!
di
H × B
L
G
di
L
H × B
G
di
L
H × B